AS 4934.2:2021 pdf free download – lncandescent Lamps for GeneralLighting Services Part 2: Energy performance and marking requirements.
This document specifies requirements (or minimum energy performance standards (MEPS). maximum wattage, and other requirements for tungsten filament, tungsten halogen and carbon filament incandescent lamps designed to produce a visible, optical radiation.
This document covers lamps as defined in ClauseJJJ that are supplied as individual lamps or as part of a luminaire.
This document does not cover the lamp types as listed in Clause L1.3.
1.1.2 Inclusions
1.1.2.1 Mains voltage Incandescent lamps
These lamps have the following attributes:
(a) Rated voltage> 140 V a.c.
(b) Lamp burner: tungsten filament tungsten halogen or carbonised material.
(c) Cap: E13, £14. £26. £27. BA15d. BlSd. B22d, GUIO. or GZ10 (as described in IEC 60061).
1.1.2.2 Incandescent lamps 11 Vto 13 V
These lamps have the following attributes:
(a) Rated Voltage I 1V and 1 3V a.c.
(b) Lamp burner: tungsten Filament tungsten halogen or carbonised material.
(c) Cap: G4, GY6.35, GU4, GZ4, GIJ5.3, GX5.3 orGS3 (as described in IEC 60061).
1.1.3 ExclusIons
1.1.3.1 Low power decorative lamps
These lamps have all of the following attributes:
(a) Rated voltage> 140 V a.c.
(b) Cap: £13, £14. £26, £27. BATSd. B1Sd. or B22d (as described in IEC 60061).
(c) Shape: round (P). candle (B), pigniy (5). tubular (T). globe (G) or pilot lamps (as described in IEC 60630).
(d) Rated power: less than 10 W.
NOTE These excluded lamps must be <2500 K or otherwise away from black body locus.
1.1.3.6 Recommended marking for excluded lamps
For lamp types as listed in Clauses LL3J. to LL3.5, it is recommended that packaging and accompanying product information state clearly and prominently theIr purpose and that they are not intended (or gineral purpose illumination.
1.2 Appilcatlon
This document shall be read in conjunction with AS/NZS 4934.1.
1.3 Normative references
The following documents are referred to In the text In such a way that some or all of their content constitutes requirements of this document.
NOTE Documents for informative purposes are listed in the Bibliography.
AS/NZS 4934.1, Incandescent lamps for general lighting ser-vice Part I: Test methods—Energy Performance
1.4 Terms and definitions
For the purposes of this document, the terms and definitions given in AS/NZS 4934.1 apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
JEC Electropedla: available at http://www.electropedla.org/
CIE e-ll.V — International Lighting Vocabulary http/Jcie.co.atJe-ilv
2 Performance and marking requirements
2.1 General
This document does not apply to the safety requirements that are covered in the AS/ NZS 60432 series or to other performance requirements that are covered in IEC 60064.
The performance criteria set out in Clauses 2.3 to 2J3 shall apply using minimum sample sizes set out in Clause 2.2.
A test report shall show conformance to this document in accordance with AS/NZS 4934.1 for each model tested. This shall contain the applicable information specified in Appendix A.
NOTE The test values are used to determine conFormance to this document.
2.2 Number of samples
The minimum sample sizes required for each test in the performance criteria Set out in Clauses 2.3 to
in accordance with AS/NZS 4934.1 shall be as follows:
(a) Initial efficacy: minimum sample size is 10.
(b) Minimum median life: minimum sample size is 20.