2.15.3 Operation
2.15.3.1 General
Each appliance shall be supplied with operating instructions, covering each separate function of the appliance and such dismantling, cleaning, and assembly as is necessary for the user, and that include reference to the Items specified in this Clause of AS/NZS 5263.0. and the following:
(aa) Details for the removal, cleaning, and replacement of any devices (such as spider guards) fitted over primary air openings.
(bb) The minimum LP Gas cylinder capacity.
2.15.4 Maintenance
2.15.4.2 ServIcing Instructions and maintenance schedule Not applicable.
2.15.4.101 Maintenance Instructions
Maintenance instructions shall be available which shall include reference to the following:
(a) Before use checks, such as cleaning the appliance and removal of accumulated grease and other cooking residue.
(b) Routine Inspection of the gas hose and regulator and a recommended replacement period of components.
(c) Check of all connections for gas soundness.
(d) Where applicable, routine inspection of the gas cylinder to check test date status.
NOTE Maintenance instructions may be incorporated into the general appliance operating instructions.
Section 4 Tests under limiting conditions
4.1 General
Appliances and their associated side burners(s) and other accessory burner(s) shall conform to the requirements of this Section when supplied with the test gases and under the limiting conditions specified in each clause, with the following exceptions:
(a) Appliances intended for use with natural gas may be tested using available natural gas but in the case of dispute or horderline results test gas ā€œNā€ shall be used.
(b) Appliances intended for use with town gas may be tested using available town gas but in the case of dispute or borderline results test gas SW shall be used.
4.2 co/co2 ratio limits of any independent surface combustion burner — linderload
When tested in accordance with Test Method Zli. 1, the CO/CO2 ratio of the combustion products of any independent surface combustion burner shall not exceed 0,02, 5 mm alter ignition, with the appliance operating at the limiting condition specified In Table 4.2.