17.1.1 Switches shall withstand without excessive wear or other harmful effect the electrical, thermal and mechanical stresses that occur in normal use.
17.1.2 The sequence of tests to be completed on the same 3 specimens is as follows:
— TC3: a test at high speed specified in 17.5.3; this test only applies to switches with more than one pole, and where the type of connection is of polarity reversal;
— TC2: a test at slow speed specified in 17.5.2,
— TC1: an increased-voltage test at accelerated speed as specified in 17.5.1; this test does not apply to switches classified according to 7.2.9;
— TC9: a locked-rotor test as specified in 17.5.5 at accelerated speed; this test only applies to switches classified according to 7.2.9;
— TC4: a test at accelerated speed as specified in 17.5.4;
followed by the requirements of 17.6.
NOTE The different types of tests are specified In 17.5.
17.1.3 When required by Clause 13, the following test, TC1O, is conducted on a different set of 3 specimens:
— TCIO: a test at very slow speed as specified in 17.5.6; this test only applies to switches according to the requirements of 13.1.
The manufacturer may choose to complete TC1O in the sequence of 17.1.2 in place of TC2.
Compliance is checked by 17.6.1 (TEl) and 17.6.3 (TE3).
17.2 Electrical endurance tests
The switch shall be loaded as specified in Table 102 and/or Table 103 and connected in accordance with the circuit as given in 61058-1:2016. Table 2.
a) Where, in IEC 61058-1:2016, Table 2, an auxiliary switch (A) is symbolized in the test circuit, the tests for the two ON-positions of the specimen (S) are performed on two separate sets of test samples. The connection to the test load to be performed for the two tests is symbolized in IEC 6 1058-1:2016, Table 2 by an auxiliary switch A.
b) Multiway switches are loaded according to 61058-1:2016. Table 1 The load for the other switch positions is that resulting from the loads necessary to achieve the conditions specified above.
C) For circuits according to 7.2.7 for specific lamp load, the connection and test load are as specified by the manufacturer using the maximum occurring inrush current at room temperature. For a specific lamp load, it is recommended that the specimen be operated with loads that are used in the field rather than with synthetic loads. Forced cooling of the specific lamp load may be applied in order to ensure cold resistance for each operating cycle and shorten the test time.
d) No electrical load is applied during the endurance tests for switches classified to 7.2.6 with a rating of 20 mA or less.
17.5 Type of test condition (TC)
17.5.1 Increased-voltage test at accelerated speed (TC1):
— Electrical conditions: The load specified according to Table 102, the voltage increased to 1, 15 the rated voltage (the load is not readjusted).
— Capacitive load and simulated lamp load tests for a.c. circuits, the test voltage Is the rated voltage and the test currents are increased to 1,15 rated currents.
— Thermal conditions: 25 °C ± 10 °C
Actuating speed: accelerated speed in 17.4.
— Operating cycles: 100.
17.5.2 Test at slow speed (TC2):
— Electrical conditions: Specified in 17.2.
— Thermal conditions: 25 °C ± 10 °C.
— Actuating speed: Slow speed in 17.4.
— Operating cycles: 100.
17.5.3 Test at high speed (TC3):
— Electrical conditions: Specified in 17.2.
— Thermal conditions: 25 °C ± 10 °C.
— Actuating speed: High speed in 17.4.
— Operating cycles: 100.
This test applies only to switches which have more than one pole and when polarity reversal occurs (when it is possible to move from one polarity to the opposite without a mechanical interlock or similar mechanical impediment).
17.5.4 Test at accelerated speed (TC4):
— Electrical conditions: specified in 17.2.
— Thermal conditions: specified in 17.3.
— Actuating speed: accelerated speed in 17.4.
— Operating cycles: Total number declared (7.4) less the number already made during tests of 17.5.1, 17.5.2 and 17.5.3.
17.5.5 Locked-rotor test (TC9):