ASME A112.19.16:2006 pdf free download.Terrazzo Plumbing Fixtures.
ASME A112.19.16 establishes the minimum requirements for terrazzo materials that are used to manufacture plumbing fixtures for general use. It includes material, structural and physical test requirements, and marking and identification of fixtures complying with this Standard.
The provisions of this Standard are not intended to prevent the use of any alternate design that meets or exceeds the intent of this Standard.
1.2 Units of Measurement
Values are stated in US. Customary units and in the International System of Units (SI). The US. Customary units shall be considered as the standard.
1.3 References
The following documents form a part of this Standard to the extent specified herein. Unless otherwise spedfied, the latest edition shall apply
ASME A112,18.2/CSA 13125.2, Plumbing Fixture Waste Fittings
Publishers: The American Society of Mechanical
Engineers (ASME), Three Park Avenue, New York,
NY 10016-5990; Order Department: 22 Law Drive,
P.O. Box 2300, Fairfield, NJ 07007-2300, and Canadian
Standards Association (CSA), 5060 Spectrum Way,
Mississauga, Ontario, Canada L4W 5N6
ASTM C 150, Standard Specifications for Portland Cement
ASTM F 4, Thermoplastic Accessible and Replaceable Mastic Tube and Tubular Fittings
ASTM F 462, Slip Resisting Bathing Facilities
Publisher: American Society of Testing and Materials (ASTM International), 100 Barr Harbor Drive, West Conshohocken, PA 1942g-2959
CSA 1345 Series, Plumbing Fixtures cSA B125.3, Plumbing Fittings
Publisher: Canadian Standards Association (CSA), 5060 Spectrum Way, Mississauga, Ontario, Canada L4W 5N6
2.2.2 Sinks. Sinks shall be one piece-molded units. The bottom shall slope toward the drain. Waste fitting openings shall be sized to accommodate standard waste fittings unless the waste outlet fitting is manufacturer- supplied.
2.2.3 Service Basin. Terrazzo service basins shall be one-piece molded units. The floor shall slope towards the drain. A drain fitting for inside caulking to a 3 in. (76 mm) pipe shall be embedded into the fixture.
2.2.4 Wash Fountains and Lavatory Systems. Wash fountain and lavatory system bowls shall be one-piece molded units with the inside bottom of the bowl sloping towards the drain so as to provide Continuous draining during use. All such bowls shall have a waste-fitting opening, the center of which is at the lowest point of the bowl. Waste4itting openings will be sized to accommodate standard waste fittings unless the waste-outlet fitting is manufacturer-supplied. Bowls shall have a minimum capacity of 21/4 gal (8.5 1.) per user. Circular and nonlinear units shall provide 20 in. (508 mm) of rim per user. Linear units shall provide 24 in. (610 mm) center- to-center distance per user section.
3.2 Slip Resistance
3.2.1 Test Method. The surfaces of the bathing area of the shower receptor shall be slip resistant and shall comply with ASTM F 462.
3.2.2 Performance Requirements. The test samples that do not comply with the performance requirements as set forth in the ASTM standard shall be cause for rejection of the product.
3.3 Surface
3.3.1 Test Method. Terrazzo bathtubs, shower receptors, wash fountains, and lavatories/lavatory systems shall meet the requirements of IAPMO/ANSI ZI 24.1.2, IAPMO/ANSI Z124.3, IAPMO/ ANSI ZI 24.6, or SA B45.5 for stain resistance, chemical resistance, wear and cleanahility, and thermal shock resistance.
3.3.2 Performance Requirements. The test samples that do not comply with the performance requirements as set forth in the applicable ANSI or CSA standard shall be cause for rejection of the product.
4 MARKING AND IDENTIFICATION
Each fixture shall be permanently marked with the manufacturer’s name or trademark. Acceptable means of applying permanent marking shall include fired-on, etching, stamping with permanent (nonwater-soluble) ink, and cast-in markings. Such marking shall be located where it can be seen after installation. Adhesive labels that comply with UI 969 shall also be considered permanent when installed on areas of the fixture that are not normally submerged in water. The exposure conditions for labels contained in para. 7.1 of UL 969 shall apply along with the additional exposure to the detergent test specified in Table 7.4 of UL 969.