ASME B73.1:2012 pdf free download.Specification for Horizontal End Suction Centrifugal Pumps for Chemical Process.
ANSI/HI 1.4, Rotodynamic (Centrifugal) Pumps for Manuals Describing Installation. Operation and Maintenance
ANSI/HI 9.1-9.5. Pumps — General Guidelines ANSI/HI 9.6.1. Rotodvnamic I’umps — Guideline for NPSH Margin
ANSI/HI 9.6.2, Rotodynamk Pumps for Assessment of Applied Nozzle L.oads
ANSI/HI 9.6.4, Rotodynamic Pumps Vibration Measurements and Allowable Values
ANSI/HI 14.6. Rotodynamic Pumps for Hydraulic
Performance Acceptance Tests
Publisher: hydraulic Institute (III), 6 Campus Drive, Parsippany, NJ 07054 (www.pumps.org)
API Std 610, Centrifugal Pumps for Petroleum, Petrochenücal and Natural Gas industries
API Std 682, Pumps — Shaft Sealing Systems for Centrifugal and Rotary Pumps
Publisher: American Petroleum Institute (API), 1220 I Street, NW, Wa.shington. DC 20005 (www.api.org)
ASME 1316.5. Pipe Flanges and flanged Fittings ASME 1316.11, Forged Steel Fittings, Socket-Welding and Threaded
ASME 516.42, Ductile Iron Pipe Flanges and Flanged Fittings: Clascs 130 and 3(10
Publisher: The American Society of Mechanical
Engineers (ASME). Two Park Avenue. New York. NY
10016-5990; Order Department: 22 Law Drive, P.O.
Bos 2900, Fairfield, NJ 07007-2900 (www.asnie.org)
ASTM A48/A48M, Standard Specification for Gray Iron Castings
ASTM A105/AIO5M. Standard Specification for Carbon Steel Forgings for Piping Applications
ASTM A106/AIO6M, Standard Specification for Seamless Carbon Steel Pipe for High-Temperature Scrvkr
ASTM A 10K, Standard Specification for Steel Bar, Carbon and Alloy, CoW-Finished
ASTM A182/AIS2M, Standard Specification for Forged or Rolled Alloy and Stainless Steel Pipe Flanges. Forged Fittings, and Valves and Parts for High- Temperature Service
5.7 Bearings, Lubrication, and Bearing Frame
5.7.1 Bearings
5.7.1.1 DesIgn. Two rolling element bearing assemblies shall be provided: one assembly free to float within the frame to carry radial loading only. and the other assembly arranged to carry both radial loading and axial thrust.
5.7.1.2 Life. Bearings shall be selected in accordance with ANSI/ABMA-9, ANSI/ABMA-Il. and 150 281. The minimum L10 bearing tile shall be 17.500 hr in the alIowaLle operating region as defined in para. 7.1.6 and for all standard and optional arrangemenls of hearings, lubrication, shafts, covers, sealing, and impellers.
5.7.1.3 End Play. The maximum end play ad the shaft assembly shall not exceed the internal axial clearance for the thrust bearing utilized. Minimum and maximum shaft end play values shall be published in the pump manufacturer’s instruction manual.
5.7.2 Lubrication
5.7.2.1 Oil bath lubrication is standard.
5.7.2.2 Oil mist lubrication shall be optional. When oil mist lubrication is specified, the location ad the inlets, drains, and the vents should he mutually agreed upon between the purchaser and the supplier.
5.7.2.3 Greased for life or regreaseable lubrication shall be optional. When regreascable lubrication is specified, a means for grease relief shall be provided.
5.7.3 Bearing Frame. Bearing frame shall be constructed to protect the bearing,s from water, dust, and other contaminants and provide lubrication for the bearings. The standard design is for oil bath lubrication and is to include labyrinth-type hearing isolators, a 1-in. (25-mm) bull’s eye oil sight gLass. magnetic drain plug, and plugged top vent
5.7.3.1 SealIng. The standard design is to include lahvnnth-type bvanng isolators. In addition, Llt,on.al designs may be offered that allow for the use of a variety of other hearing frame seals, such as lip seals or magnetic oil seals, as may be specified by the purchaser. in those cases where the bearing frame seal does not allow the hearing frame prrs’.ua to equalize with atmospheric pressure during operation, an expansion chamber or breather is necessary.
5.7.3.2 Bearing Frame Drain. Bearing frame shall he provided with a tapped and plugged drain hole at its lowest point. A magnetic drain plug shall be used.
57.3.3 Lubricant Leve4 Indication. Bearing frame for oil bath lubrication shall be provided with a 1-in. (25-rnni) buids eve level indicator that is capable of optionally being installed on either side or both sides