IEC 60110-1:1998 pdf download - Power capacitors for induction heating installations - Part 1: General

IEC 60110-1:1998 pdf download – Power capacitors for induction heating installations – Part 1: General

Posted by

IEC 60110-1:1998 pdf download – Power capacitors for induction heating installations – Part 1: General.
This part of IEC 60110 is applicable both to indoor capacitor unit5 and indoor capacitor banks intended to be used, particularly, for power factor correction in induction heating, melting. stirring or casting installations, and similar applications with controlled or adjustable ac. voltage systems in a frequency range up to 50 kHz, and with a rated voltage not exceeding 3.6 kV.
Additional requirements br capacitors protected by internal element fuses are given in
IEC 60110-2.
The following capacitors are excluded Iron, this standard:
— series capacitors for power systems (see IEC 60143):
— capacitors for motor applications arid the like (see IEC 60252);
— coupling capacitors and capacitor dividers (see IEC 60358);
— shunt power capacitors of the self’healing type for a.c. systems having a rated voltage up to and including 1 000 V (see IEC 60831):
— shunt capacitors for a.c. power systems having a rated voltage above 1 000 V (see
IEC 60871):
— shunt capacitors of the non-self-healing type for ac. systems having a rated voltage up to and including 1 000 V (see IEC 60931);
— small ac. capacitors to be used tot fluorescent and discharge lamps (see IEC 61048 and
IEC 61049);
— capacitors lobe used in power electronic circuits (see IEC 61071);
— capacitors for microwave ovens (see IEC 61270);
— capacitors for suppression of radio interference (under consideration);
— capacitors intended for use with d.c. voltage superimposed on the ac. voltage
Accessories such as insulators, switches, instrument transformers, fuses. etc.. shall be in
accordance with the relevant lEG standards.
The object of this standard is:
a) to formulate uniform rules regarding performance, testing and rating;
b) to formulate specific safety rules:
C) to provide a guide for installation and operahon.
1.2 Normative referencea
The following normative documents contain provisions which, through reference in the text. constitute provisions of this part of IEC 60110. At the time of publication, the editions indicated were valid. All normative documents are subject to revision, and parties to agreements based on this part of lEG 60110 are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below Members of IEC and ISO maintain registers of currently valid International Standards.
IEC 60050(436):1 990. International Electrotechnical Vocabulary (1EV) — Chapter 436: Power capacitors
IEC 601 10-2, — Power capacitors to, induction heating Installations — Part 2: Ageing test, destruction test and requirements for disconnecting internal fuses I
lEG 60143, Series capacitors for power systems
IEC 60831. — Shunt power capacitors of the self-heahng type for ac. systems having a rated voltage up to and including 1 000 V
IEC 60871, — Shunt capacitors for a.c. power systems having a rated voltage above 1 000 V
IEC 60931, — Shunt power capacitors of the non-self-healing type for a.c. systems having a rated voltage up to and including 1 000 V
IEC 60996:1989. Method for verifying accuracy of tan delta measurements applicable to capacitors
1.3 DefinItions
For the purpose of this part of IEC 60110. the following definitions apply:
1.3.1
(capacitor) element
device consisting essentially of two electrodes separated by a dielectric. 11EV 436.01.03]
1.3.2
(capacitor) unit
assembly of one or more capacitor elements in the same container with terminals brought out.
[1EV 436-01-04)
1.3.3
self-healing capacitor
capacitor the electric properties of which, after local breakdown of the dielectric, are rapidly and essentially reslored (1EV 436.03-12).

Leave a Reply