IEC 60317-7:1997 pdf download - Specifications for particular types ofwinding wires - Part 7: Polyimide enamelled round copper wire,class 220

IEC 60317-7:1997 pdf download – Specifications for particular types ofwinding wires – Part 7: Polyimide enamelled round copper wire,class 220

Posted by

IEC 60317-7:1997 pdf download – Specifications for particular types ofwinding wires – Part 7: Polyimide enamelled round copper wire,class 220.
Class 220 is a thermal class mat requires a minimum temperature index of 220 and a heat shock temperature of at least 240 C.
The temperature in degrees Celsius corresponding to the temperature index is not necessarily that at which it is recommended that me wire be operated and this will depend on many factors. including the type of equipment involved,
The range of nominaJ conductor diameters covered by this standard is:
— Grade 1: 0,020 mm up to and induding 2,000 mm;
— Grade 2: 0,020 mm up to and indudirig 5,000 mm.
The nominal conductor cbameters are specified wi clause 4 of IEC 60317-0-1.
2 NormatIve references
The following standard contains provisions which. through reference In this text, constitute provisions of this International Standard. At the time of publication, the edsion indicated was valid. All standards are subject to revision, and parties to agreements based on this International Standard are encouraged to Investigate me possibility of applying the most recent edition of the standard indicated below, Members of IEC and ISO maintain registers of currently valid international standards
IEC 60317-0-1: 1990. Specificatons for parfictdar types of nd,ng wires – Part 0: General requirements – Section 1: Enamelled round copper wtre
3 DefinitIons and general notes on methods of test
For definitions and general notes on methods of test see clause 3 of IEC 60317-0-1.
In case of inconsistencies between IEC 60317-0-1 and this standard, IEC 60317-7 shall prevail.
4 DimensIons
See clause 4 of IEC 60317-0•1.
5 Electrical resistance
See clause 5 of IEC 60317-0-I.
6 ElongatIon
See clause 6 of IEC 80317.0-1,
7 SpringIness
See clause 701 IEC 60317-0-1.
8 FlexibilIty and adherence
See clause B of IEC 6031 7-01 where the constant K used for the calculation of the number of revolutions for the peel test shall be 90 mm.
9 Heat shock
See clause 9 of IEC 60317-0-1 where the minimum heat shock terrerature shall be 240 ‘C.
10 Cut-through
No failure shall occur within 2 mu at 400 ‘C.
11 Resistance to abrasion (nominal conductor diameters from 0,250 mm up to and including 2,500 mm)
The wire shall meet the requirements given in table 1.