IEC 60770-1:1999 pdf download – Transmitters for use in industrial-processcontrol systems – Part 1: Methods for performance evaluation.
This part of IEC 60770 is applicable to transmitters which have either a standard analo9ue electric current output signal or a standard pneumatic output sgnal in accordance with lEG 60381-1 or IEC 60382. The tests detailed herein may be applied to transmitters which have other output signals, provided that due allowance is made for such differences.
For certain types of transmitters where the sensor is an integral part, other specific IEC or ISO standards may need to be consulted (eg. for chemical analysers. flowmeters. etc.)
This standard is intended to specify uniform methods of test for the evaluation of the performance of transmitters with pneumatic or electric output signals.
The methods of evaluation specified in this standard are intended tot use by manufacturers to determine the performance of their products and by users or independent testing establishments to verify manufacturers’ performance specitications.
The test Conditions detined in this standard, for example the range of ambient temperatures and power supply, represent those which commonly arise in use, Consequently, the values specified herein should be used where no other values are specified by the manufacturer.
The tests specified in this standard are not necessarily sufficient for instruments specifically designed for unusually arduous or safety related duties. Conversely, a restricted series of test may be suitable for instruments designed to perform within a more limited range of conditions.
When a full evaluation in accordance with this standard is not required, those tests which are required shall be performed and the results reported in accordance with those parts of the standard which are relevant.
2 NormatIve references
The following normative documents contain provisions which, through reference in this text. constitute provisions of this part 01 IEC 60770. At the time of publication, the editions indicated were valid. All normative documents are subject to revslon, and parties to agreements based on this part of lEG 60770 are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below Members of IEC and ISO maintain registers of currently valid International Standards
lEG 60068-2-1:1990, Environmental testing — Part 2: Tests — Test A: Cold
lEG 60068-2-2:1974, Environmental testing — Part 2: Tests — Test B: Dry heat
IEC 60068-2.31:1969, Environmental teslvng — Part 2: Tests — Test Ec: Drop and topple, primarily for equipment-type specimens
lC 60381-1:1982. Analogue signals for process control systems — Part 1: Direct current signals
IEC 60382:1991, Analogue pneumatic signal for process control systems IEC 60529:1989. Degrees of protection provided by enclosures (IP Code)
lEG 60902:1987. Industrial-process measurement and control — Terms and definitions
IEC 61000-4-2:1995, Electromagnetic compatibility (EMC) — Part 4: Testing and measurement techniques — Section 2: Electrostatic discharge Immunity test. Basic EMC Publication
IEC 61 000-4-3:1 998. Electromagnetic compatibility (EMC) – Part 4-3: Testing and measurement techniques — Radiated, radio-frequency electromagnetic field immunity test
IEC 61000-4-4:1995, Electromagnetic compatibility (EMC) — Part 4: Testing and measurement techniques — Section 4: Electrical fast transient.bursts immunity test. Basic EMC Publication
IEC 61 000-4-5:1995, Electromagnetic compatibility (EMC) — Part 4: Testing and measurement techniques — Section 5: Surge immunity test
IEC 61 000-4-6:1996, Electromagnetic compatibility (EMC) — Part 4: Testing and measurement techniques — Section 6: Immunity to conducted disturbances induced by radio-frequency fields
IEC 61000-4-8:1993, Electromagnetic compatibility (EMC) — Part 4: Testing and measurement techniques — Section 8: Power Ire quency magnetic field immunity test. Basic EMC Publication
lEG 61000-4-10:1993. Electromagnetic compatibility (EMC) — Part 4: Testing and measurement techniques – Section 10: Damped oscillatory magnetic field Immunity test. Basic EMC Publication
IEC 61000-4-11:1994, Electromagnetic compatibility (EMC) — Part 4: Testing arid measurement techniques — Section 11: Voltage dips. short interruptions and voltage variations immunity test
lEG 61000-4-12:1995, Electromagnetic compatibility (EMC) — Part 4: Testing and measurement techniques — Section 12: Oscillatory waves Immunity test. Basic EMC Publication
IEC 61000-4-16:1998. Electromagnetic compatibility (EMC) — Part 4-16: Testing and measurement techniques — Test for immunity to conducted, common mode disturbances in the frequency range 0 lIz to 150 kHz
IEC 61010-1:1990, Safety requirements for electrical equipment for measurement, control, and laboratory use — Part 1: General requirements
lEG 61032:1997. Protection of persons and equipment by enclosures – Probes for verification.